ab

a

OUTDO Energy Storage Battery

1.Adopting low-Calcium & high-Tin alloy grid, high anti-corrosive performance, low battery gas evolution;
2.With special lead paste formula, our batteries have good endurance cycle capability and charging acceptance and good recovery performance after deep cycle use;
3.The fumed silica that is adopted as the key raw material of gel electrolyte is produced in germany;
4.Batteries have long service life, good deep discharging cycle capability;
5.Gel batteries have better heat dissipation than AGM sealed batteries, reduced the possibility of thermal runaway;
6.The self-discharge of gel batteries is less than 1%/month;
7.The electrolyte inside battery equally distributed has no layering phenomenonand the electrolyte is not readily to dry up;
8.Battery producing adopts high purity raw material, advanced manufacturing equipment to ensure battery performance stability and consistency;
9.Battery electrolyte contains silica sol, so no dissociative acid or layering phenomenon inside, ensure the good low temperature performance and service life of batteries;
10.Battery design life of standby use at 25℃ is over 10 years.

abx

Safety Notice for Using

Battery Use

1.Batteries are delivered fully charged. During the storage before installation, the capacity of battery will decrease in different degrees. If the storage time is longer, battery should be recharged. If the storage time is less than 6 months, batteries should be recharged in constant voltage limit current 2.27V/Cell, the maximum current should be less than 0.25 C A, charging time 48~72h.
2.Batteries could be in standby use and cycle use. Please charge the battery in constant voltage and limit current, the maximum current : 0.1C10~0.25 C10 A, battery standby use: 25℃ 2V series: 2.25V/Cell, 6V or 12V series: 2.27V/Cell; battery cycle use: 25℃, 2V series: 2.35V/Cell, 6V or 12V series: 2.40V/Cell.
3.If the ambient temperature is too high or too low, in case the ambient temperature exceeds 20℃~30℃, then the charging voltage should be adjusted, in case of higher temperature, decreases the charging voltage, and in lower temperature increases the charging voltage, the correction factor : 4mV/℃. Besides, that ambient temperature of battery is too high or too low will also influence the capacity and the service life.
4.Battery should be recharged after the installation or after the discharging, charging the battery in constant voltage limit current mode, charging voltage: 25℃ 2.35V/Cell, the maximum current: 0.1C10~0.25C10 A, if discharging in 100% capacity, the charging time is about 24h-27h, if the charging current decreases to a very low current, and retain for 3h almost invariant or the charging electric quantity is 1.15 times of the discharging electric quantity, then consider the battery have been fully charged.
5.Battery equalization charging: while the float voltage of the certain battery or some of the batteries is under 2.2V/Cell, then the whole pack of batteries should be equalization recharged, 25℃ 2.35V/Cell, the maximum current: 0.1C10~0.15 C10 A, time: 8h~12h.

Requirements of Installation and Use

1.Generally, battery are used in series connection, if batteries must be used in parallel connection, then the parallels should not be over two branches. 
2.Batteries can work in an ambient temperature of -25℃~45℃. The proper using temperature is 15℃~30℃, the battery room should have necessary ventilation.
3.Batteries should be away from source of heat and spark, the security distance should be longer than 1 meter. Batteries should be stored away from direct sunlight, other rays, organic solvent gases and corrosive gases. To improve shockproof capability, the battery rack should be reinforced with foundation bolts.
4.Batteries are delivered fully charged, so during the transportation and installation, batteries should be prevented from short circuit, be careful of the short circuit caused by batteries and metal parts of battery metal shelf or metal box touches.
5.When installing the battery wires, the operator should use insulating tools and wear insulating gloves, also remove personal metal articles like watch, bracelets and so on.
6.The operator should screw the bolt tightly during the connection, the proper torque should be 5~7N.M in case of battery overheating or battery striking fire caused by loose connection.
7.Batteries of different models or different capacity cannot be mixed in use. When installing terminal connecting pieces, operators should carefully inspect if the polarity connecting is correct. The positive pole of battery connects with the positive pole of charging device, the negative pole of battery connects with the negative pole of charging device, be careful not to reverse the polarity.

Requirements of Battery Working Maintenance

1.During the battery working, the operator should take complete working records including battery voltage, current, ambient temperature and other relevant data and working time.
2.Operators should inspect the fastening condition of connecting terminals such as battery overheating or striking fire caused by the connecting strip smudge or loose connecting.
3.Inspecting the total float charging voltage, the operator should use voltmeter to measure the measurement number of battery positive and negative output end voltage is consistent with the indicating float charge voltage, and conforms to the required number of standard float charge voltage under the current temperature. 
4.During the battery working, if battery voltage is abnormal, appearance has damage like battery container and cover has flaw or deformation), battery electrolyte leaks, battery temperature is normal, the operator should find the failure cause in time.
5.The appearance of battery should be cleared by clean water, organic solvent is not allowed. Be sure that battery use has a dry, clean, ventilated environment.

Notes for Battery Use

1.Don’t separate or transform the battery.
2.Don’t throw the battery into the water or the fire.
3.Please wear insulating gloves when connecting the battery packs.
4.Don’t install, use or store batteries in which children can touch.
5.Don’t use different brand, different capacity, different voltage and different degree of old and new batteries in series connection.
6.There is acid inside batteries, if battery is damaged by machine and acid splash the skin, clothes and even eyes, please wash with plenty of water or seek medical treatment immediately.

OUTDO

Digital Display Intelligent Motocycle
Battery

DS-iGEL is a type of electronic battery with LCD screen which real-time
monitors the status of battery and records the battery used days.There
is alarm when detecting the volts is abnormal or the battery is short of
capacity which reminds the user to maintain timely and prolong the
service life of battery.

ert3
tc123

Alarm for Abnormality

There is alarm when detecting the volts is abnormal or the battery is short of capacity
which reminds the user to maintain timely and prolong the service life of battery.

Push-to-open Lid Cover

Adding acid for maintenance by opening
lid cover to prolong the battery service life

zdf

Injected with Gel electrolyte
instead of acid, the battery is
of super performance.

◆ Higher capacity.
◆ Good performance in the low temperatures, can meet requirements of starting currents in -30℃ to -50℃
◆ Stable characteristic in high temperatures, can meet requirements of its usage in temperature of 65℃ and even higher.
◆  Longer cycle service life than normal lead acid battery type.

Safe Use Precautions

Warning

1. The inside electrolyte will corrode metal, cotton product, stone. Use properly.
2. Do not place the battery against the side or upside down to prevent acid leakage
3. The hydrogen will be generated during the working and discharging of battery which will cause explosion if there were fire. Pay attention for the following
3.1. Maintain and use the battery where is ventilate
3.2. No sparks and flame when the battery is in maintenance
3.3. If the battery is charging outside the vehicle which can’t be installed immediately after finish charging until laying at lease 10min to release the hydrogen generated inside
the battery.
3.4. After riding, the battery can’t be dismounted immediately until laying for at least 10 mins
3.5. During charging, the ambient temperature should not be over 45℃, Otherwise cooling by water or by reducing the charging current and charging volts.
4. DO NOT place the metal tool or conducting matter nearby the terminal in case short-circuit the terminal
5. DO not knock the terminal by hammer during the battery installation
6. Be safe during carrying to prevent hitting

 

Installation and Maintenance

1. Always connect the positive terminal firstly.
DO NOT reverse polarity otherwise the electrical equipment of motorcycle will damage.
Caution:
*Some can’t be activated due to the different performance of different vehicle. Start the engine for more times or step on gas which can more easily to activate.
*Manual activation is recommend to achieve exact date recorded.
2. During acid filling, wearing acid-proof cloths, rubber boots, shield glass and rubber glove etc.
   If the skin and clothes are splashed by acid, wash by large quantity of water. Seek medical help if necessary.
3. DO NOT over discharging the battery, charging the battery timely after discharging.
4. Dismount or disconnect the negative terminal of battery if the motorcycle hasn’t been in service for long term.
5. DO NOT check the battery has power or not by short-circuit the terminal.
6. Regularly check the terminal connection and the surface of terminal is clean or not to ensure well connection.
7. Storage the battery where is 5~25℃, dry, ventilated and no direct sunshine. Keep the battery at least 2m away from the heat source. Regularly check and maintain the battery.

module2_2

Two Options of Charging

XT60 charging port

According to the different situation,The user can freely choose the charging by solar panel or by the charger.

module3_2
module6_1_A
module6_1_B

Filling packs inside the top cover

When the battery has been in service for 400-500 days, please follow the cover sheet

illustration for refilling liquid. After being refilled, the service life of
the system is expected to extend by 15%-30%.
Some models do not have this function, users can ask professionals to perform
fluid replacement (deionized water) maintenance.

Safe Use Precautions

Safety Precautions
1. Do not dismantle for repair or modify, or the system of sulfuric acid, lead will cause harm to people and the environment.
2. Do not shorten the positive and negative terminals of the system or system group,otherwise it will cause electric shock, fire or malfunction.
3. Please firmly connected to the terminal part of the bolt, if loose will become the cause of the fire.
4. Do not contaminate oil, water or other chemicals, otherwise there will be electric shock,fire, and the cause of the malfunction.
5. Be sure to cut off the mains power when installing the connection, and there is a risk of electric shock
6. Do not connect to a power supply other than the rated voltage, otherwise there will be a fire and the cause of the malfunction.
7. Do not use the system directly as AC power, otherwise it will become a fire, fault, damage reasons. (To make the system as an AC power supply, you
mustuse special equipment such as UPS.)
8. Do not place the system near fire, heat or fire, so as not to cause an explosion
9. Charging process will produce trace gas, when using, please pay attention to ventilation and heat dissipation and maintain in the ventilation conditions.

Precautions for Use

1.Do not store and use in the following cases, otherwise it will
   be fault, acid leakage, leakage and other reasons
1.1. Outdoor and other places where direct rain or sunshine.
1.2. Foggy or icing places.
1.3. Locations with corrosive gases.
1.4. Humid heavier or dusty places.
1.5. Occurrence of shock or shock.
1.6. It should be stored in a cool, dry, clean environment.

2. LCD screen maintenance
2.1. Avoid hard objects to oppress the control panel.
2.2. Keep the screen, the interface clean and dry.
2.3. Always check the system display.
2.4. Be aware of the buzzer alarm.
2.5. Handle timely when the system alarms
2.6. System LCD screens and the circuit board shall be waterproof damp-proof,in the use of wet conditions, the LCD screen and system  could be in  abnormalfunctions.

tc121-removebg-preview
3

LCD Screen

Real-time monitors the system status and alarms
when the system is abnormal.

4

Filling packs inside the top cover

When the battery has been in service for 400-500 days, please follow the cover sheet illustration for refilling liquid.

After being refilled, the service life of the system is expected to extend by 15%-30%.
Part of items are without this function, users can ask professionals to add distilled warter to maintain.

Safe Use Precautions

Safety Precautions

1. Do not dismantle for repair or modify, or the system of sulfuric acid, lead will cause harm to people and the environment.
2. Do not shorten the positive and negative terminals of the system or system group, otherwise it will cause electric shock, fire or malfunction.
3. Please firmly connected to the terminal part of the bolt, if loose will become the cause of the fire.
4. Do not contaminate oil, water or other chemicals, otherwise there will be electric shock, fire, and the cause of the malfunction.
5. Be sure to cut off the mains power when installing the connection, and there is a risk of electric shock.
6. Do not connect to a power supply other than the rated voltage, otherwise there will be a fire and the cause of the malfunction.
7. Do not use the system directly as AC power, otherwise it will become a fire, fault, damage reasons. (To make the system as an AC power supply, you must use special equipment such as UPS.)
8. Do not place the system near fire, heat or fire, so as not to cause an explosion.
9. Charging process will produce trace gas, when using, please pay attention to ventilation and heat dissipation and maintain in the ventilation conditions.

Precautions for Use

1. Do not store and use in the following cases, otherwise it will be fault, acid leakage, leakage and other reasons
1.1. Places below -40℃ or above + 50℃.
1.2. Outdoor and other places where direct rain or sunshine. 
1.3. Foggy or icing places.
1.4. Locations with corrosive gases.
1.5. Humid heavier or dusty places.
1.6. Occurrence of shock or shock.
1.7. It should be stored in a cool, dry, clean environment.

2. LCD screen maintenance
2.1. Avoid hard objects to oppress the control panel.
2.2. Keep the screen, the interface clean and dry.
2.3. Always check the system display.
2.4. Be aware of the buzzer alarm.
2.5. Handle timely when the system alarms
2.6. System LCD screens and the circuit board shall be waterproof damp-proof, in the use of wet conditions, the LCD screen and system could be in abnormal functions.

module2_2

Two Options of Charging

XT60 charging port

According to the different situation,The user can freely choose the charging by solar panel or by the charger.

module3_2
module6_1_A
module6_1_B

Filling packs inside the top cover

When the battery has been in service for 400-500 days, please follow the cover sheet

illustration for refilling liquid. After being refilled, the service life of
the system is expected to extend by 15%-30%.
Some models do not have this function, users can ask professionals to perform
fluid replacement (deionized water) maintenance.

Safe Use Precautions

Safety Precautions
1. Do not dismantle for repair or modify, or the system of sulfuric acid, lead will cause harm to people and the environment.
2. Do not shorten the positive and negative terminals of the system or system group,otherwise it will cause electric shock, fire or malfunction.
3. Please firmly connected to the terminal part of the bolt, if loose will become the cause of the fire.
4. Do not contaminate oil, water or other chemicals, otherwise there will be electric shock,fire, and the cause of the malfunction.
5. Be sure to cut off the mains power when installing the connection, and there is a risk of electric shock
6. Do not connect to a power supply other than the rated voltage, otherwise there will be a fire and the cause of the malfunction.
7. Do not use the system directly as AC power, otherwise it will become a fire, fault, damage reasons. (To make the system as an AC power supply, you
mustuse special equipment such as UPS.)
8. Do not place the system near fire, heat or fire, so as not to cause an explosion
9. Charging process will produce trace gas, when using, please pay attention to ventilation and heat dissipation and maintain in the ventilation conditions.

Precautions for Use

1.Do not store and use in the following cases, otherwise it will
   be fault, acid leakage, leakage and other reasons
1.1. Outdoor and other places where direct rain or sunshine.
1.2. Foggy or icing places.
1.3. Locations with corrosive gases.
1.4. Humid heavier or dusty places.
1.5. Occurrence of shock or shock.
1.6. It should be stored in a cool, dry, clean environment.

2. LCD screen maintenance
2.1. Avoid hard objects to oppress the control panel.
2.2. Keep the screen, the interface clean and dry.
2.3. Always check the system display.
2.4. Be aware of the buzzer alarm.
2.5. Handle timely when the system alarms
2.6. System LCD screens and the circuit board shall be waterproof damp-proof,in the use of wet conditions, the LCD screen and system  could be in  abnormalfunctions.

module2_2

Two Options of Charging

XT60 charging port

According to the different situation,The user can freely choose the charging by solar panel or by the charger.

module3_2
module6_1_A
module6_1_B

Filling packs inside the top cover

When the battery has been in service for 400-500 days, please follow the cover sheet

illustration for refilling liquid. After being refilled, the service life of
the system is expected to extend by 15%-30%.
Some models do not have this function, users can ask professionals to perform
fluid replacement (deionized water) maintenance.

Safe Use Precautions

Safety Precautions
1. Do not dismantle for repair or modify, or the system of sulfuric acid, lead will cause harm to people and the environment.
2. Do not shorten the positive and negative terminals of the system or system group,otherwise it will cause electric shock, fire or malfunction.
3. Please firmly connected to the terminal part of the bolt, if loose will become the cause of the fire.
4. Do not contaminate oil, water or other chemicals, otherwise there will be electric shock,fire, and the cause of the malfunction.
5. Be sure to cut off the mains power when installing the connection, and there is a risk of electric shock
6. Do not connect to a power supply other than the rated voltage, otherwise there will be a fire and the cause of the malfunction.
7. Do not use the system directly as AC power, otherwise it will become a fire, fault, damage reasons. (To make the system as an AC power supply, you
mustuse special equipment such as UPS.)
8. Do not place the system near fire, heat or fire, so as not to cause an explosion
9. Charging process will produce trace gas, when using, please pay attention to ventilation and heat dissipation and maintain in the ventilation conditions.

Precautions for Use

1.Do not store and use in the following cases, otherwise it will
   be fault, acid leakage, leakage and other reasons
1.1. Outdoor and other places where direct rain or sunshine.
1.2. Foggy or icing places.
1.3. Locations with corrosive gases.
1.4. Humid heavier or dusty places.
1.5. Occurrence of shock or shock.
1.6. It should be stored in a cool, dry, clean environment.

2. LCD screen maintenance
2.1. Avoid hard objects to oppress the control panel.
2.2. Keep the screen, the interface clean and dry.
2.3. Always check the system display.
2.4. Be aware of the buzzer alarm.
2.5. Handle timely when the system alarms
2.6. System LCD screens and the circuit board shall be waterproof damp-proof,in the use of wet conditions, the LCD screen and system  could be in  abnormalfunctions.

Safe Use Precautions

Warning

1. The inside electrolyte will corrode metal, cotton product, stone. Use properly.
2. Do not place the battery against the side or upside down to prevent acid leakage
3. The hydrogen will be generated during the working and discharging of battery which will cause explosion if there were fire. Pay attention for the following
3.1. Maintain and use the battery where is ventilate
3.2. No sparks and flame when the battery is in maintenance
3.3. If the battery is charging outside the vehicle which can’t be installed immediately after finish charging until laying at lease 10min to release the hydrogen generated inside  the battery.
3.4. After riding, the battery can’t be dismounted immediately until laying for at least 10 mins
3.5. During charging, the ambient temperature should not be over 45℃, Otherwise cooling by water or by reducing the charging current and charging volts.
4. DO NOT place the metal tool or conducting matter nearby the terminal in case short-circuit the terminal
5. DO not knock the terminal by hammer during the battery installation
6. Be safe during carrying to prevent hitting

Installation and Maintenance

1. Always connect the positive terminal firstly.
DO NOT reverse polarity otherwise the electrical equipment of motorcycle will damage.
Caution:
*Some can’t be activated due to the different performance of different vehicle. Start the engine for more times or step on gas which can more easily to activate.
*Manual activation is recommend to achieve exact date recorded.
2. During acid filling, wearing acid-proof cloths, rubber boots, shield glass and rubber glove etc.
   If the skin and clothes are splashed by acid, wash by large quantity of water. Seek medical help if necessary.
3. DO NOT over discharging the battery, charging the battery timely after discharging.
4. Dismount or disconnect the negative terminal of battery if the motorcycle hasn’t been in service for long term.
5. DO NOT check the battery has power or not by short-circuit the terminal.
6. Regularly check the terminal connection and the surface of terminal is clean or not to ensure well connection.
7. Storage the battery where is 5~25℃, dry, ventilated and no direct sunshine. Keep the battery at least 2m away from the heat source. Regularly check and maintain the battery.

tc121-removebg-preview
3

LCD Screen

Real-time monitors the system status and alarms
when the system is abnormal.

4

Filling packs inside the top cover

When the battery has been in service for 400-500 days, please follow the cover sheet illustration for refilling liquid.

After being refilled, the service life of the system is expected to extend by 15%-30%.
Part of items are without this function, users can ask professionals to add distilled warter to maintain.

Safe Use Precautions

Safety Precautions

1. Do not dismantle for repair or modify, or the system of sulfuric acid, lead will cause harm to people and the environment.
2. Do not shorten the positive and negative terminals of the system or system group, otherwise it will cause electric shock, fire or malfunction.
3. Please firmly connected to the terminal part of the bolt, if loose will become the cause of the fire.
4. Do not contaminate oil, water or other chemicals, otherwise there will be electric shock, fire, and the cause of the malfunction.
5. Be sure to cut off the mains power when installing the connection, and there is a risk of electric shock.
6. Do not connect to a power supply other than the rated voltage, otherwise there will be a fire and the cause of the malfunction.
7. Do not use the system directly as AC power, otherwise it will become a fire, fault, damage reasons. (To make the system as an AC power supply, you must use special equipment such as UPS.)
8. Do not place the system near fire, heat or fire, so as not to cause an explosion.
9. Charging process will produce trace gas, when using, please pay attention to ventilation and heat dissipation and maintain in the ventilation conditions.

Precautions for Use

1. Do not store and use in the following cases, otherwise it will be fault, acid leakage, leakage and other reasons
1.1. Places below -40℃ or above + 50℃.
1.2. Outdoor and other places where direct rain or sunshine. 
1.3. Foggy or icing places.
1.4. Locations with corrosive gases.
1.5. Humid heavier or dusty places.
1.6. Occurrence of shock or shock.
1.7. It should be stored in a cool, dry, clean environment.

2. LCD screen maintenance
2.1. Avoid hard objects to oppress the control panel.
2.2. Keep the screen, the interface clean and dry.
2.3. Always check the system display.
2.4. Be aware of the buzzer alarm.
2.5. Handle timely when the system alarms
2.6. System LCD screens and the circuit board shall be waterproof damp-proof, in the use of wet conditions, the LCD screen and system could be in abnormal functions.

1(2)

OUTDO

Characteristic of Flooded
Rechargeable Lead Acid Battery

1. 100% Pre-delivery inspection to ensure stable quality and reliable performance
2. Pb-Ca grid alloy battery plate, low water loss, and stable quality low self-discharge rate.
3. Low internal resistance, good high rate discharge performance
4. The flooded electrolyte design, sufficient electrolyte, high over-charge/over-discharge resistance.
5. Excellence high-and-low temperature performance, working temperature ranging from -30℃ to 55℃.
6. Design float service life: 3-5 years.

Safe Use Precautions

Warning
1. The inside electrolyte will corrode metal, cotton product, stone. Use properly.
2. Do not place the battery against the side or upside down to prevent acid leakage
3. The hydrogen will be generated during the working and discharging of battery which will cause explosion if there were fire. Pay attention for the following
3.1. Maintain and use the battery where is ventilate
3.2. No sparks and flame when the battery is in maintenance
3.3. If the battery is charging outside the vehicle which can’t be installed immediately after finish charging until laying at lease 10min to release the hydrogen generated inside
the battery.
3.4. After riding, the battery can’t be dismounted immediately until laying for at least 10 mins
3.5. During charging, the ambient temperature should not be over 45℃, Otherwise cooling by water or by reducing the charging current and charging volts.
4. DO NOT place the metal tool or conducting matter nearby the terminal in case short-circuit the terminal
5. DO not knock the terminal by hammer during the battery installation
6. Be safe during carrying to prevent hitting

Installation and Maintenance
1. Always connect the positive terminal firstly.
DO NOT reverse polarity otherwise the electrical equipment of motorcycle will damage.
Caution:
*Some can’t be activated due to the different performance of different vehicle. Start the engine for more times or step on gas which can more easily to activate.
*Manual activation is recommend to achieve exact date recorded.
2. During acid filling, wearing acid-proof cloths, rubber boots, shield glass and rubber glove etc.
If the skin and clothes are splashed by acid, wash by large quantity of water. Seek medical help if necessary.
3. DO NOT over discharging the battery, charging the battery timely after discharging.
4. Dismount or disconnect the negative terminal of battery if the motorcycle hasn’t been in service for long term.
5. DO NOT check the battery has power or not by short-circuit the terminal.
6. Regularly check the terminal connection and the surface of terminal is clean or not to ensure well connection.
7. Storage the battery where is 5~25℃, dry, ventilated and no direct sunshine. Keep the battery at least 2m away from the heat source. Regularly check and maintain the battery.

tc130

OUTDO

Characteristic of Valve Regulated
GEL Battery

1. 100% Pre-delivery inspection to ensure stable quality and reliable performance
2. Pb-Ca grid alloy battery plate, low water loss, and stable quality low self-discharge rate.
3. Complete sealed, maintenance free, low self-discharge rate, good sealing property.
4. Low internal resistance, good high rate discharge performance
5. Excellence high-and-low temperature performance, working temperature ranging from -40℃ to 60℃.
6. High charge retention, long cycle service life
7. Design float service life: 3-5 years.

Push-to-open Lid Cover

Adding acid for maintenance by opening
lid cover to prolong the battery service life.


Injected with Gel electrolyte
instead of acid, the battery is
of super performance.

◆ Higher capacity;
◆ Good performance in the low temperatures, can meet requirements of starting currents in -30℃ to -50℃;
◆ Stable characteristic in high temperatures, can meet requirements of its usage in temperature of 65℃ and even higher.
◆ Longer cycle service life than normal lead acid battery type.

Safe Use Precautions

Warning

1. The inside electrolyte will corrode metal, cotton product, stone. Use properly.
2. Do not place the battery against the side or upside down to prevent acid leakage
3. The hydrogen will be generated during the working and discharging of battery which will cause explosion if there were fire. Pay attention for the following
3.1. Maintain and use the battery where is ventilate
3.2. No sparks and flame when the battery is in maintenance
3.3. If the battery is charging outside the vehicle which can’t be installed immediately after finish charging until laying at lease 10min to release the hydrogen generated inside
      the battery.
3.4. After riding, the battery can’t be dismounted immediately until laying for at least 10 mins
3.5. During charging, the ambient temperature should not be over 45℃, Otherwise cooling by water or by reducing the charging current and charging volts.
4. DO NOT place the metal tool or conducting matter nearby the terminal in case short-circuit the terminal
5. DO not knock the terminal by hammer during the battery installation
6. Be safe during carrying to prevent hitting

Installation and Maintenance
1. Always connect the positive terminal firstly.
DO NOT reverse polarity otherwise the electrical equipment of motorcycle will damage.
Caution:
*Some can’t be activated due to the different performance of different vehicle. Start the engine for more times or step on gas which can more easily to activate.
*Manual activation is recommend to achieve exact date recorded.
2. During acid filling, wearing acid-proof cloths, rubber boots, shield glass and rubber glove etc.
If the skin and clothes are splashed by acid, wash by large quantity of water. Seek medical help if necessary.
3. DO NOT over discharging the battery, charging the battery timely after discharging.
4. Dismount or disconnect the negative terminal of battery if the motorcycle hasn’t been in service for long term.
5. DO NOT check the battery has power or not by short-circuit the terminal.
6. Regularly check the terminal connection and the surface of terminal is clean or not to ensure well connection.
7. Storage the battery where is 5~25℃, dry, ventilated and no direct sunshine. Keep the battery at least 2m away from the heat source. Regularly check and maintain the battery.

Safety Notice for Using

 

Battery Use

1.Batteries are delivered fully charged. During the storage before installation, the capacity of battery will decrease in different degrees. If the storage time is longer, battery should be recharged. If the storage time is less than 6 months, batteries should be recharged in constant voltage limit current 2.27V/Cell, the maximum current should be less than 0.25 C A, charging time 48~72h.
2.Batteries could be in standby use and cycle use. Please charge the battery in constant voltage and limit current, the maximum current : 0.1C10~0.25 C10 A, battery standby use:25℃ 2V series: 2.25V/Cell, 6V or 12V series: 2.27V/Cell; battery cycle use: 25℃, 2V series: 2.35V/Cell, 6V or 12V series: 2.40V/Cell.
3.If the ambient temperature is too high or too low, in case the ambient temperature exceeds 20℃~30℃, then the charging voltage should be adjusted, in case of higher temperature, decreases the charging voltage, and in lower temperature increases the charging voltage, the correction factor : 4mV/℃. Besides, that ambient temperature of battery is too high or too low will also influence the capacity and the service life.
4.Battery should be recharged after the installation or after the discharging, charging the battery in constant voltage limit current mode, charging voltage: 25℃ 2.35V/Cell, the maximum current: 0.1C10~0.25C10 A, if discharging in 100% capacity, the charging time is about 24h-27h, if the charging current decreases to a very low current, and retain for 3h almost invariant or the charging electric quantity is 1.15 times of the discharging electric quantity, then consider the battery have been fully charged.
5.Battery equalization charging: while the float voltage of the certain battery or some of the batteries is under 2.2V/Cell, then the whole pack of batteries should be equalization recharged, 25℃ 2.35V/Cell, the maximum current: 0.1C10~0.15 C10 A, time: 8h~12h.

Requirements of Installation and Use

1.Generally, battery are used in series connection, if batteries must be used in parallel connection, then the parallels should not be over two branches.
2.Batteries can work in an ambient temperature of -25℃~45℃. The proper using temperature is 15℃~30℃, the battery room should have necessary ventilation.
3.Batteries should be away from source of heat and spark, the security distance should be longer than 1 meter. Batteries should be stored away from direct sunlight, other rays,organic solvent gases and corrosive gases. To improve shockproof capability, the battery rack should be reinforced with foundation bolts.
4.Batteries are delivered fully charged, so during the transportation and installation, batteries should be prevented from short circuit, be careful of the short circuit caused by batteries and metal parts of battery metal shelf or metal box touches.
5.When installing the battery wires, the operator should use insulating tools and wear insulating gloves, also remove personal metal articles like watch, bracelets and so on.
6.The operator should screw the bolt tightly during the connection, the proper torque should be 5~7N.M in case of battery overheating or battery striking fire caused by loose connection.
7.Batteries of different models or different capacity cannot be mixed in use. When installing terminal connecting pieces, operators should carefully inspect if the polarity connecting is correct. The positive pole of battery connects with the positive pole of charging device, the negative pole of battery connects with the negative pole of charging device, be careful not to reverse the polarity.

Requirements of Battery Working Maintenance

1.During the battery working, the operator should take complete working records including battery voltage, current, ambient temperature and other relevant data and working time.
2.Operators should inspect the fastening condition of connecting terminals such as battery overheating or striking fire caused by the connecting strip smudge or loose connecting.
3.Inspecting the total float charging voltage, the operator should use voltmeter to measure the measurement number of battery positive and negative output end voltage is consistent with the indicating float charge voltage, and conforms to the required number of standard float charge voltage under the current temperature.
4.During the battery working, if battery voltage is abnormal, appearance has damage like battery container and cover has flaw or deformation), battery electrolyte leaks, battery temperature is normal, the operator should find the failure cause in time.
5.The appearance of battery should be cleared by clean water, organic solvent is not allowed. Be sure that battery use has a dry, clean, ventilated environment.

Notes for Battery Use

1.Don’t separate or transform the battery.
2.Don’t throw the battery into the water or the fire.
3.Please wear insulating gloves when connecting the battery packs.
4.Don’t install, use or store batteries in which children can touch.
5.Don’t use different brand, different capacity, different voltage and different degree of old and new batteries in series connection.
6.There is acid inside batteries, if battery is damaged by machine and acid splash the skin, clothes and even eyes, please wash with plenty of water or seek medical treatment immediately.